Monday, February 20, 2012

VMware PEX 2012

 

clip_image002

Training and competencies are important, and I am pleased to attend various training courses and product events throughout the year, one of them being the VMware Partner Exchange (VMware PEX), held this year in Las Vegas from Feb. 10-17, 2012. It is the second PEX event I’ve attended.

VMware PEX is a showcase event run by VMware and designed specifically for VMware Partners. It is sponsored by many of the vendors—including EMC and Cisco. There were over 4,000 attendees and it was a great opportunity to network with other like-minded individuals and VMware professionals to discuss issues and problems that occur on a daily basis. It was also a chance to upgrade my credentials: this year I took and passed the VMware Certified Professional 5 (VCP 5) exam.

At VMware PEX (Partner Exchange), some interesting statistics were revealed:

  • Someone in the world powers up a new Virtual Machine every 6 seconds
  • There are now more than 25 million Virtual Machines running on VMware
  • More than 50% of the world’s workloads are now run on Virtual Machines
  • 81% of all virtualized workloads run on VMware

VMware has built their virtualization foundation upon vSphere. I have been actively assisting customers to virtualize their environments. After virtualizing their servers, many customers are further interested in virtualizing their desktops using VMware View—also called VDI (Virtual Desktop Infrastructure). Many organizations are using VMware View to allow for centralized management and easy access to virtual desktops.

As a leader in the virtualization space, VMware is always looking to the future, and this year was no exception. They are building upon their solid foundation and have created two new products: VMware vCloud Director (vCD) and VMware vCentre Operations Server (vCOPS).

VMware vCloud Director (vCD) allows organizations to look at their datacentres in a whole new way—rather than refer to individual servers, or even clusters of servers, vCD allows an organization to view their datacentre as a group of resources that they can utilize and deploy in any fashion they wish. They can give individual departments access to infrastructure without those departments having to a) purchase new gear or b) know anything about the underlying infrastructure. The IT department takes care of the underlying infrastructure and adds more servers, networking and storage as required. Other departments can simply consume these resources as needed using an easy to understand web-based interface. vSphere virtualizes the server; vCloud Director virtualizes the entire datacentre.

VMware vCentre Operations Server (vCOPS) is a monitoring and analytic engine that gives the organziation the ability to watch over the datacentre (or multiple datacentres) and collect metrics. It learns what is “normal” in your environment and will alert you to anomalies. It also provides trending so the organization can be made proactively aware that they will, for example, run out of diskspace in 6 months based on previous trends. This allows the organization to actively plan for the future instead of guessing at potential issues or dealing with them on the fly. In addition, when problems do arise, it allows the organization to pinpoint problems and know exactly what piece is causing the issue.clip_image004

In addition, VMware PEX hosts break-out sessions and hands-on labs where Partners can test out products in a live environment. This year, there were over 190 breakout sessions on many different topics and 27 different hands-on labs.

On the 2nd last night, VMware had a party for all attendees with the Bare Naked Ladies – and I took some footage.

Overall, the experience was fantastic and I would highly recommend that customers attend the customer-open event “VMWorld” in 2012.

Jim Nickel

VMware VCP5

UPS, vSphere, APCUPSD, PowerCLI and IPMI

 

One area that I feel is overlooked when dealing with VMware vSphere environments is UPS. Many organizations have a UPS and also a backup generator. But they don’t have a nice way of shutting everything down gracefully. I have heard that they don’t need that because of the generator, so the power will never be out.  But what happens if the generator doesn’t work correctly?

Anyway…I wanted a system for my home lab to shut everything down nicely and then bring it back up in the correct order.

I own a APC UPS that is a 1500 VA. Off of that, I run 2 of the Tyan motherboard white box ESXi 5 servers, 1 HP ML 350 G4p running ESX 4.0, a Linksys 48 port switch, one small iSCSI server using the Starwind software and one large storage server also running the Starwind Software iSCSI target.

All that runs about 68% load capacity on the UPS – I should probably get another one and split the load – but I will do that later.  This UPS is connected to the large storage server via a Serial cable so it can handle the monitoring duties.

So….I want have the following procedure in the event of a power failure:

  1. Shut down the VMs.
  2. Shut down the ESXi hosts.
  3. Send a “kill” command to the UPS so it turns off the power after a grace period (3 mins).
  4. Shut down the storage servers.

So….Point #3 – this is important because I want the servers to come back on automatically once power is restored.  If the UPS itself doesn’t shut off then the servers won’t see that as a power failure and won’t come back on once power is restored.

Also…it is important to note that the BIOS setting of the storage servers must be adjusted so that they are set to “Power On” in the event of a power loss. However, I must set the ESXi servers to NOT “Power On” in the event of a power loss – why?  You ask?

The problem is that the new ESXi 5 servers boot way faster than the iSCSI storage servers, so they are up before the storage is. And if that happens then the VM’s obviously won’t start.

So….since my fancy new servers (actually under $500 each!) have builtin IPMI – I will have a script on the storage server that will power them on and start up the VM’s once the storage server is started back up. This will ensure that everything comes back up in the correct order.

APCUPSD

First I downloaded and installed the apcupsd application – I found it much easier to use and understand than the standard PowerChute software – however, PowerChute or any other UPS monitoring application that can run scripts will work just fine.

Once installed, you have to adjust the apcupsd.conf file.  Since I installed my application in C:\apcupsd, mine was in c:\apcupsd\etc\apcupsd\apcupsd.conf and looks like this:

UPSCABLE 940-0095A
UPSTYPE apcsmart
DEVICE COM1
UPSCLASS standalone
UPSMODE disable
TIMEOUT 30

This configuration only gives me 30 seconds of running on the batteries before everything is going to start shutting down.  For me, I don’t have a lot of run time and any power outage longer than 30 seconds is likely to last longer than the run time of my batteries so it works for me….do what works for you.

Next, you have to adjust the apccontrol.bat file in that same directory. There is one spot that allows you to “Kill” the UPS (have it shut itself off) after a shutdown so that everything will come back up when the power is restored.  It is the section labelled “doshutdown”

:doshutdown
rem
rem  If you want to try to power down your UPS, uncomment
rem    out the following lines, but be warned that if the
rem    following shutdown -h now doesn't work, you may find
rem    the power being shut off to a running computer :-(
rem  Also note, we do this in the doshutdown case, because
rem    there is no way to get control when the machine is
rem    shutdown to call this script with --killpower. As
rem    a consequence, we do both killpower and shutdown
rem    here.
rem  Note that Win32 lacks a portable way to delay for a
rem    given time, so we use the trick of pinging a
rem    non-existent IP address with a given timeout.
rem

   %APCUPSD% /kill
   ping -n 1 -w 5000 10.255.255.254 > NUL
   %POPUP% "Doing %APCUPSD% --killpower"
   %APCUPSD% --killpower
   ping -n 1 -w 12000 10.255.255.254 > NUL
   %SHUTDOWN% -h now
   GOTO :done

Also…you need to change the apcupsd server to have a “-p” in order for the “KILL” UPS command to work:

apcupsd.exe /service –p

You can hack the registry, but probably the easiest way is to just delete the service and re-create it with the SC command:

sc create test binPath= "C:\apcupsd\bin\apcupsd.exe /service -p"

Once that is done, you need to create your .BAT file and your PowerCLI script to actually perform the shutdown actions.  The above script – apccontrol.bat – will “CALL” other scripts based on the action – so….my 30 second timeout is an action called “Timeout”.  So…I create a timeout.bat in that same directory.  Here is what mine looks like:

%SystemRoot%\system32\windowspowershell\v1.0\powershell.exe -psc "C:\Program Files (x86)\VMware\Infrastructure\vSphere PowerCLI\vim.psc1" -NoLogo -NonInteractive -ExecutionPolicy RemoteSigned -Command "C:\UPS\PowerOffAll.ps1"

shutdown /s /m \\192.168.1.56

The first command runs the PowerCLI script I have called “PowerOffAll.ps1” in the C:\UPS directory. Since we are running this from the APCUPSD service, it is important that we have the –ExecutionPolicy RemoteSigned in there or it won’t work – even if you have already set that policy. The next line simply connects to the 2nd storage server to shut it down too – the reason it works is because I am using the same username/password combination on both storage servers.

Thanks needs to go to Mike Foley for pointing out the ExecutionPolicy tip!  Thanks!

PowerCLI

For shutting everything down, I wanted to use PowerCLI. First I downloaded/installed PowerCLI from VMware. I found a number of scripts that did almost what I wanted and just modified and combined till I got what I wanted:

start-transcript -path c:\UPS\shutdownlog.txt

Set-PowerCLIConfiguration -DefaultVIServerMode multiple -Confirm:$false

# Connect to each ESX(i) server
Connect-VIServer 192.168.1.60,192.168.1.65 -user 'root' -password 'password'

# set the startup options on each VM - changed to using a auto start PowerCLI script on boot instead
#Get-VM -Name "SBS" | Get-VMStartPolicy | Set-VMStartPolicy -StartAction PowerOn -StartOrder 1
#Get-VM -Name "vCenter" | Get-VMStartPolicy | Set-VMStartPolicy -StartAction PowerOn -StartOrder 2
#Get-VM -Name "PBX In A Flash" | Get-VMStartPolicy | Set-VMStartPolicy -StartAction PowerOn -StartOrder 3
#Get-VM -Name "YNWP" | Get-VMStartPolicy | Set-VMStartPolicy -StartAction PowerOn -StartOrder 4
#Get-VM -Name "WHS" | Get-VMStartPolicy | Set-VMStartPolicy -StartAction PowerOn -StartOrder 5

# For each of the VMs on the ESX hosts
Foreach ($VM in Get-VM){
    # Shutdown the guest cleanly
    $VM | Shutdown-VMGuest -Confirm:$false
}

# Set the amount of time to wait before assuming the remaining powered on guests are stuck
$waittime = 180 #Seconds
sleep 10.0
do {
    # Wait for the VMs to be Shutdown cleanly
    sleep 10.0
    $waittime = $waittime - 10
    $numvms = @(Get-VM | Where { $_.PowerState -eq "PoweredOn" }).Count
    Write "Waiting for shutdown of $numvms VMs or until $waittime seconds"
} until ((@(Get-VM | Where { $_.PowerState -eq "PoweredOn" }).Count) -eq 0 -or $waittime -le 0)

Write "About to shutdown ESXi hosts"
# Shutdown the ESX Hosts
sleep 5.0
Get-VMHost | Foreach {Get-View $_.ID} | Foreach {$_.ShutdownHost_Task($TRUE)}

Write-Host "Shutdown Complete"
Disconnect-VIServer 192.168.1.60,192.168.1.65 -Confirm:$False

Stop-Transcript

I wanted a log of everything, so I used the Start-Transcript command. I also want to handle all of the ESXi servers directly in one group instead of talking to the vCenter – this is for 2 reasons – 1) my vCenter is virtual, so if it shuts down as part of the process, I won’t be able to talk to it to handle the rest of the shutdown process and 2) I don’t want to have to connect to each ESXi server individually. The other benefit is that when I do a “Get-VM”, it does it across all the ESXi servers. One easy modification would be to get the list of ESXi hosts from vCenter and then connect to them. That way you wouldn’t have to modify/hard code the addresses into this script.

My original idea was to set the startup/shutdown options in each ESXi server and allow it to start them up in the correct order.  However, with HA, the startup/shutdown options don’t work anymore and besides, if a machine gets vMotioned, then it won’t necessarily be the 1st to come up out of all the VM's on all the ESXi servers. So…I decided to go with a script to start things up on boot instead. I left the code in case someone else wants to use it.

So…next it shuts down all the VMs (this requires that VMware Tools is installed in all VMs!). Then it waits up to 180 seconds for all VMs to poweroff. Once that has happened, or the time has expired, it shuts down all the ESXi hosts.

Then my original batch file shuts off the 2nd storage server and then finally the apccontrol.bat sends the kill command to the UPS and shuts off the main storage server.

Startup and IPMI

Now…when the power comes back on, the BIOS of the 2 ESXi servers is set to stay off, but the BIOS of the 2 storage servers is set to Power On. So…they come back on. Then, I have a scheduled task in the main storage server that is set to run on boot.

All I need now is a command from Windows that this scheduled task can run to turn the ESXi servers back on, and then another PowerCLI command to actually start up the VMs in the order I want.

I had a heck of a time getting ahold of a copy of IPMITool for Windows. Sun used to make one, but Oracle bought out Sun a few years ago. They still have it, but it is much harder to find. So…find it here.

Once you have it unzipped, you can run a command like the one below to power on your server:

ipmitool-1.8.10.3-3.win.i386.exe -I lan -H 192.168.1.160 -U root –P password chassis power on

Lastly, we need a PowerCLI script to power on all the VMs in the right order. This isn’t written yet – so I will have to update this post later on once I have completed it.

I hope this is useful to someone!

Jim

Sunday, January 29, 2012

Backups

 

I tried and tried to get my previous off-site backup to work reliably, but in the end, it just wasn’t reliable…not what you want from a backup.

I tried both Livedrive and also Onlinestoragesolution and neither was particularly reliable. The thing I liked about them was that I could use them to store stuff – almost like an archive – but if I can’t depend on them, they are useless.

I have moved to using Crashplan.  They don’t have an archiving solution, but the backups have been reliable. I have been using them for about 8 months now. Initially, I had a few issues with the backups not going as fast as they should, but I worked with their techs and got it resolved.

For $6/month you can get a Family Plan which allows up to 10 machines to backup an unlimited amount of data. Additionally, for free – you can turn your own machine into a backup target for your friends and family – and they can do the same.

It has worked really well for me – no complaints. They even have a iPhone app so you can download something from your backup to your iPhone if/when you need to. I just wish it had an archiving feature and the ability to use FTP, but you just can’t get everything. I will take reliable over features everytime.

Home Lab Upgrade–vSphere 5, Tyan Motherboard and iSCSI Multipathing

 

I have been running my home lab on two old HP ML350’s and they have been work horses – very reliable and stable, but not particularly fast and not 64 bit capable.

I have been wanting to try out a number of the new features of vSphere 5 and also run a number of Windows 2008 R2 64 bit OS instances, so I knew an upgrade was in order.

My current home lab consists of 2 HP ML350’s with 6 GB of RAM each, a Linksys 48 port Gigabit switch and my Norco multi-terabyte storage server that is running the free Starwind Software as an iSCSI target.

The setup has worked remarkably well and has allowed me to explore many different setups, but the time has come for an upgrade.

My initial thought was to find and buy some used gear that is on the VMware HCL, like maybe a couple of HP DL360 G5’s.  They would run me about $700 each.  After reviewing Jase's home lab build though, I decided to go ahead with something similar.

In the article, Jase goes with some more powerful CPU’s, but I decided that a) I always find that I run out of RAM before CPU in a VMware environment and b) I didn’t need the extra features that the other CPU’s provide – like VT-d (VMware DirectPass Through) etc. More important to me was cost.

So….here is what I purchased:

Tyan S5510GM3NR motherboard
Intel G620 2.6Ghz CPU with 3MB cache
Kingston KVR1333D3E9S/4G RAM (2 of these for 8 GB of RAM, could put in 4 for 16 GB of RAM)
Rosewill Case – FBM-01 RTL
Rosewill PSU – RG530-S12 530W RT

I ordered everything from Newegg.ca and my total cost (in CAD) was around $970 for 2 of these systems.

One motherboard from Newegg was DOA (dead on arrival), so I requested a Advanced Replacement from them (doesn’t cost extra and you get your stuff much sooner, plus you get a return shipment label).

So, I built one system.

What a GREAT MOTHERBOARD! 3 completely compatible NIC’s, 4 DDR3 slots so I can upgrade RAM easily, KVM over IP or also called IPMI and I could easily have put in a CPU that had 4 or more cores without too much more expense.

I just couldn’t get the motherboard to boot via the IPMI web interface, so I connected up a USB DVD drive directly to the system.

Also….the motherboard has a internal USB stick connection just ready and waiting to take a USB stick to boot and run from – so that is what I did – I bought a couple 4 GB Patriot USB drives and installed ESXi 5 directly onto that. Afterwards, you need to change your scratch drive to another location in order for your logs to be saved between reboots.

The other nice thing about this motherboard is that it has 3 NIC ports – one doubles as the IPMI port, but it can still be used by ESXi too.

The only bad thing I found about the gear I bought was that the motherboard expects a Front Fan to be hooked up to it and the fans that come with the case are only two wire fans that just take a power connection from the PSU.  Without the fan hooked to the motherboard, the motherboard squeals constantly to say that there is an alarm – a fan has stopped spinning – at least that it what it thinks. So, I ended up purchasing a couple $9 fans from a local store that had the 4 wire connections and replacing the front 120MM fans in the cases. Then all was good.

So, then I setup Round-Robin iSCSI multipathing – this is different from how it was in vSphere 4. VMware has added a GUI to allow this to be done directly from the VI Client.

Here is how that was done:

First I created the combined network like this – all three adapters as part of one vSwitch.

image

However, the iSCSI multipathing requires that each VMKernel port has only 1 uplink connection – so you have to make multiple VMKernel ports, assign them IP's and then override the default switch failover order for that VMkernel port.

image

Then you add the iSCSI storage adapter, and add the two VMkernel interfaces in the Network Configuration tab of the iSCSI Initiator properties.

image

Once that is done, you setup your iSCSI targets in the Dynamic Discovery tab as normal.

When finished, and you right-click a iSCSI target LUN/Disk, you will see multiple paths to the iSCSI target. Simply change the Path Selection to Round Robin and you are done!

image

Pretty darn happy with this new setup!

Saturday, July 16, 2011

Virtual Openfiler 2.3 with Mirrored Boot Disks (vSphere/ESX)

 

I have seen a number of installations of Openfiler on ESX, but I haven’t seen any that fully show the installation I was looking for.

In my case, I have an ESX with 2 – 1 TB disks. I don’t have a RAID controller in the machine, so the disks just show up in ESX as individual drives.

ESX with individual disks

In order to provide redundancy of any data stored on these local disks, I decided to install Openfiler.

Openfiler is a Linux distribution that allows any disks attached to it (in this case virtual disks – or VMDKs) to be shared out as iSCSI or NFS. I am going to use iSCSI as it performs better in Openfiler (in my opinion). This means that even the ESX server that is hosting the Openfiler will see its’ own disks through the virtualization layer of Openfiler.

This has the side benefit of making the local disk available to all other ESX servers as shared storage. However, the main reason I wanted to do this was redundancy – I want to make the 2 individual disks look like a single RAID 1 volume and thus have the data stored in 2 different places.

ESX with Openfiler

The big difference in my case is that I am going to make 2 boot disks and mirror them – however, one boot disk will be on local storage and the other on existing shared storage. The reason is that if a physical drive in the ESX server was to die, and it happened to be the boot disk for the ESX server, I would have a hard time getting the Openfiler back up. This way, I just stick the other disk into another server (or reinstall ESX on another disk), re-attach the data volumes to the Openfiler and I am back in business!

On to the implementation!

You could potentially use the ESX appliance available from www.openfiler.com, but I decided to use the ISO and create a new installation. As I didn’t have 64 bit hardware, I used the 2.3 x86 version of Openfiler.

I choose Red Hat Enterprise Linux 5 (32bit) as the OS Type and gave it 512 MB of RAM.

When creating my new Openfiler VM, I gave it 5 GB of disk on different existing SHARED storage and 5 GB of disk on one of the local disks. Not sure that I would want to create both boot disks (we will end up with 2) on the local storage – if one of the physical disks died, and I lost the ESX, I want to be able to get my data back by just sticking the other physical disk into another server and re-attaching the disk to the Openfiler.  Anyway…that is your decision.

I am going to have one boot disk on separate shared storage and one on the local storage.

I begin the installation of Openfiler and skip the Media test.

After the initial steps we get to the partition manager. In our case, the hard disks are called:sda and sdb. This can be different in your case. We'll create the /boot partition first:

  1. Choose Manually partition with Disk Druid.
  2. Click New.
  3. Select the following options:
    • File System Type: Software RAID
    • Allowable Drives: sda
    • Size (MB): 102
    • Additional Size Options: Fixed Size
    and click OK.

Now, repeat this (from step 2) for the other hard disk, sdb (selected in step 3). After that, make a RAID-1 partition from both individual partitions:

  1. Click RAID.
  2. Select Create a RAID device [default=/dev/md0], and click OK.
  3. Select the following options:
    • Mount Point: /boot
    • File System Type: ext3
    • RAID Device: md0
    • RAID Level: RAID1
    • RAID Members: sda and sdb checked
    and click OK.

That's our first RAID-1 partition. Now, repeat all these steps for the / partition. As for the /swap partition, create them on both disks but don't create a RAID-1 partition for them (just choose File System Type: swap in step 3 and skip step 4, 5 and 6).

 

 

 

 

 

Now manually assign a static IP, let the install finish and reboot.

Login as root using the password you assigned during installation.

Now we need to update to the latest version:

conary updateall
conary update kernel
reboot


In the unfortunate case that one of the hard disks fails, we should make them both bootable. This can be done with GRUB (GRand Unified Bootloader):

$ grub
device (hd0) /dev/sda
root (hd0,0)
setup (hd0)
device (hd1) /dev/sdb
root (hd1,0)
setup (hd1)
quit
Now we want to install VMware Tools

Guest->Install VMware Tools


cd /root
mount /dev/cdrom /mnt/cdrom
cp /mnt/cdrom/VMwareTools-4.0.0-208167.tar.gz .
tar -xvzf VMwareTools-4.0.0-208167.tar.gz
cd vmware-tools-distrib
If you run ./vmware-install.pl at this point, you will find that a number of modules are already installed and must be removed before you can proceed. So….


rm /lib/modules/2.6.29.6-0.30.smp.gcc3.4.x86.i686/kernel/fs/vmblock/vmblock.ko
rm /lib/modules/2.6.29.6-0.30.smp.gcc3.4.x86.i686/kernel/fs/vmhgfs/vmhgfs.ko
rm /lib/modules/2.6.29.6-0.30.smp.gcc3.4.x86.i686/kernel/drivers/misc/vmci/vmci.ko
rm /lib/modules/2.6.29.6-0.30.smp.gcc3.4.x86.i686/kernel/drivers/misc/vmmemctl/vmmemctl.ko
rm /lib/modules/2.6.29.6-0.30.smp.gcc3.4.x86.i686/kernel/drivers/net/vmxnet/vmxnet.ko


./vmware-install.pl


Pick the defaults for all questions except answer /usr/bin/make for the gcc compiler question.


What is the location of the "gcc" program on your machine? /usr/bin/make


reboot


Add additional disks, RAID them and present them as LUNs to ESX in the normal fashion. If I get time, I will show this part too.

Thursday, May 5, 2011

MX Guarddog Review

 

Every once in a while, you come across a nice little diamond in the rough.

Check out http://www.mxguarddog.com

You put a small text based link somewhere on your site and you get free spam and virus filtering service!

Registration and setup were easy. I did this for myself and then I did it for a client.

You change your MX records to point to the ones owned by mxguarddog and then configure mxguarddog to forward your “clean” mail to your regular mail server.

For myself this was easy as I run my own virtual exchange server.

For my client, I ran into a problem as the client was being hosted on a 3rd party and they didn’t give me access to everything in the cPanel so things didn’t work right away. I had to get the MX records changed – but then things broke.

I contacted mxguarddog support – they got back to me in a matter of minutes – diagnosed the problem and told me how to fix it.  I contacted the 3rd party hosting company, got them to select the option: “Always accept mail locally even if the primary mx does not point to this server.” – or Local Exchanger (depends on your version of cPanel).

Voila! Pain free Spam and Virus filtering!

You can add multiple domains to a single account – you can whitelist, blacklist.

My only suggestion would be that they let you see statistics about the numbers of mail messages delivered, spam, virus etc.

Overall – I give this a 9.5 out of 10….fantastic!

One technical note: In order to really benefit from a service like this, you need to restrict your mail server to only allow mail from the mxguarddog.com servers – look at their instructions for the IP’s you need to allow.  Otherwise, spammers may still try to send mail directly to your server bypassing the MX Guarddog guys – and there isn’t much they can do about mail they don’t get.

free spam filter  cloud based spam filter

Wednesday, March 23, 2011

EA–Need For Speed Shift

 

I play XBox 360 video games.  Mostly just racing, but I will delve into some other genres too.

One title I enjoy is NFS Shift – I even pre-ordered the next iteration – Shift 2.

Even though there are tons of bugs in the game, it is still fun to play.  Fun online, fun in Career mode.

However, when playing online there are number of things that make things unfair – and one of them specifically is cheating. There is a major flaw in the online game that allows users to use a higher rating car than they should.  Now I don’t really care if everyone has the cheat, cause then it is fair again – everyone can do it and no one has a major advantage.

A better option is to FIX THE GAME!

So….I sent Electronic Arts (EA) a support ticket telling them about the game. I got no response. So I posted in a few forums and tried to get a response. Nothing.

Then I posted the cheat on a few forums and explained again to EA. How did they respond?

Did they fix the game so that this wouldn’t keep happening?  NO…they don’t care about that, they don’t give a crap about quality control or investing any more money in a game that is already history. Not that they did a very good job on quality control during the construction of the game or even the patches they released afterwards.

What did they do?  They banned ME.  Yup…try to do a good thing – report bugs – and get banned from using their product. Nice…..what stupid jerks.  They can’t spend the money to fix it, so they want to just try and hide it – make sure people don’t know about it.

Imagine you were getting shitty service from your phone company – you would tell people about it. You would also call and complain to the phone company. And then…what if they disconnected your phone line because you have been complaining to other people about it?  That is not reasonable – they would fix the phone line.  EA needs to grow up.

The other problem is, 30-40% of the people online are all using the cheat already.  So….that means that it is unfair for the rest of the players that are trying to use the system too. So hiding the fact that there is a major flaw isn’t solving anything.

EA has a policy of banning those that a) use a cheat, or b) post about how to use a cheat.  Like this solves anything.

FIX YOUR DAMN SOFTWARE!

So…just so everyone can have it….here is the post I made about NFS Shift:

Heya....I am posting this not because I want everyone to cheat, but because I want everyone to have a level playing field.


I have reported this to EA, but they don't seem to care and I am tired of seeing people beat me when I know they are cheating. There are so many bugs in this game, but EA seems to care more about pushing out the game than quality control. What pisses me off so much is that I like the game - if I didn't, I just wouldn't bother to play - it could be sooo much better - I really wish EA gave a CRAP!

I am not saying I am the fastest, but I am not bad - people don't usually beat me around Road America by 10 seconds a lap for example - I can do a 1:52 in unrestricted and a 2:03 in a 14 car.

Anyway - if everyone can have the same cheats, then it is fair again.

Major bug - Online play lets you use higher rated cars in lower levels:
For example, use a 17 level car in a game restricted to 14 level cars.
These steps have to be done everytime you restart the game, but it doesn't take long and many people are doing it.
To reproduce:
1) Purchase stock Z06 - if you already own it, sell it and rebuy it (you will not lose tuning settings)
2) Go into XBox Live
3) Create a Ranked match, Race, 14 level cars and accept it
4) Pick your Z06 from your list of cars
5) Exit the race (no need to actually race)
6) Go to the Car Garage and upgrades
7) Purchase all upgrades (except Works Convert - this bug didn't seem to work for me when I Works Converted)
8) Go back into XBox Live
9) Either create a match, or join one and when the car rating is 14, your Z06 will be chosen by default even though it is now a 17+ rated car

This also works for any level - for example, you can take the Porsche Cayman - use it as a 10 car when it is actually setup for a 14 car.


Use it while you can - I am hoping EA will fix this. I have posted this information to them and on a number of forums, so hopefully they will actually do something about it.